Omri Posted on 2005-08-09 08:21:44.0Z
Sender: 1fcd.42f86294.1804289383@sybase.com
From: Omri
Newsgroups: ianywhere.public.general
Subject: problem in comunication
X-Mailer: WebNews to Mail Gateway v1.1t
Message-ID: <42f86798.2056.1681692777@sybase.com>
NNTP-Posting-Host: 10.22.241.41
X-Original-NNTP-Posting-Host: 10.22.241.41
Date: 9 Aug 2005 01:21:44 -0700
X-Trace: forums-1-dub 1123575704 10.22.241.41 (9 Aug 2005 01:21:44 -0700)
X-Original-Trace: 9 Aug 2005 01:21:44 -0700, 10.22.241.41
Lines: 32
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4674
Article PK: 8480

i am trying to program ppc to synchronize with the mobilink.
i succeded when i did with GPRS now i tried it wity WiFi and
it gave me: "communication error" i don't under stand the
immportance of the way that it's connected as long that you
connect to the net.

here is my code :
try
{
ConnDown.SyncParms.Stream = StreamType.TCPIP ;
ConnDown.SyncParms.StreamParms
"host=xxx.xx.xx.xx;port=2439";
ConnDown.SyncParms.Version = "test1";
ConnDown.SyncParms.UserName = "user";
ConnDown.SyncParms.Password = "abc1234";
ConnDown.SyncParms.SendDownloadAck = true;
ConnDown.Synchronize();
if (!ConnDown.SyncResult.UploadOK )
MessageBox.Show(ConnDown.SyncResult.StreamErrorSystem.ToString()
);
}
catch(SQLException err)
{
MessageBox.Show("err 10: " + err.Message );
}



please tell me if something wrong.

have a good day
Omri Ziv


David Fishburn Posted on 2005-08-09 12:40:11.0Z
Newsgroups: ianywhere.public.general
Subject: Re: problem in comunication
From: David Fishburn <fishburn_spam@off.ianywhere.com>
References: <42f86798.2056.1681692777@sybase.com>
Organization: iAnywhere Solutions
Message-ID: <Xns96AD582F0E7ACfishburnsybasecom@127.0.0.1>
User-Agent: Xnews/06.08.25 Hamster/2.0.6.0
NNTP-Posting-Host: fishburn-t30.sybase.com
X-Original-NNTP-Posting-Host: fishburn-t30.sybase.com
Date: 9 Aug 2005 05:40:11 -0700
X-Trace: forums-1-dub 1123591211 10.25.98.148 (9 Aug 2005 05:40:11 -0700)
X-Original-Trace: 9 Aug 2005 05:40:11 -0700, fishburn-t30.sybase.com
Lines: 64
X-Authenticated-User: techsupp
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4675
Article PK: 8476

Omri wrote in news:42f86798.2056.1681692777@sybase.com of
ianywhere.public.general:

O> i am trying to program ppc to synchronize with the mobilink.
O> i succeded when i did with GPRS now i tried it wity WiFi and
O> it gave me: "communication error" i don't under stand the
O> immportance of the way that it's connected as long that you
O> connect to the net.
O>
O> here is my code :
O> try
O> {
O> ConnDown.SyncParms.Stream = StreamType.TCPIP ;
O> ConnDown.SyncParms.StreamParms
O> "host=xxx.xx.xx.xx;port=2439";
O> ConnDown.SyncParms.Version = "test1";
O> ConnDown.SyncParms.UserName = "user";
O> ConnDown.SyncParms.Password = "abc1234";
O> ConnDown.SyncParms.SendDownloadAck = true;
O> ConnDown.Synchronize();
O> if (!ConnDown.SyncResult.UploadOK )
O> MessageBox.Show
(ConnDown.SyncResult.StreamErro
O> rSystem.ToString()
O> );
O> }
O> catch(SQLException err)
O> {
O> MessageBox.Show("err 10: " + err.Message );
O> }

You are correct, the SyncParms settings should be identical between the
GPRS and WiFi settings.

Now, generally GPRS is coming in from the internet and WiFi is already
behind the corporate firewall.

Did you try starting a ML server on your desktop to see if it can be
reached via WiFi?

You need to narrow things down a bit, and try different ML servers on
different parts of your network.

--
David Fishburn
Certified ASA Developer Version 8
iAnywhere Solutions - Sybase
Professional Services
Please only post to the newsgroup
Please ALWAYS include version and MORE importantly BUILD number with
EACH post (dbeng9 -v).

EBFs and Maintenance Releases
http://downloads.sybase.com/swx/sdmain.stm

Developer Community / Whitepapers
http://www.ianywhere.com/developer

CaseXpress - to report bugs
http://casexpress.sybase.com

CodeXchange - Free samples
http://ianywhere.codexchange.sybase.com/servlets/ProjectDocumentList


Omri Posted on 2005-08-09 13:55:39.0Z
Sender: 1fcd.42f86294.1804289383@sybase.com
From: Omri
Newsgroups: ianywhere.public.general
Subject: Re: problem in comunication
X-Mailer: WebNews to Mail Gateway v1.1t
Message-ID: <42f8b5db.2810.1681692777@sybase.com>
References: <Xns96AD582F0E7ACfishburnsybasecom@127.0.0.1>
NNTP-Posting-Host: 10.22.241.41
X-Original-NNTP-Posting-Host: 10.22.241.41
Date: 9 Aug 2005 06:55:39 -0700
X-Trace: forums-1-dub 1123595739 10.22.241.41 (9 Aug 2005 06:55:39 -0700)
X-Original-Trace: 9 Aug 2005 06:55:39 -0700, 10.22.241.41
Lines: 28
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4676
Article PK: 8477

D> You are correct, the SyncParms settings should be
D> identical between the GPRS and WiFi settings.
D>
D> Now, generally GPRS is coming in from the internet and
D> WiFi is already behind the corporate firewall.
D>
d> Did you try starting a ML server on your desktop to see
if
d> it can be reached via WiFi?
d>
d> You need to narrow things down a bit, and try different
ML
d> servers on different parts of your network.
d>
d> --
first of all you right:
mobilink 9.0.2.3044
ultralite 9.0.1
and the language is c#
before i synchronize i'm doing ping to the computer and i
get success.
but when i use the synchronize i get communication error on
the spot it's not even tring to make a connection it's
throwin the exception immediatley


thank you in advence
Omri Ziv


Greg Fenton Posted on 2005-08-10 15:05:45.0Z
From: Greg Fenton <greg.fenton_NOSPAM_@ianywhere.com>
Organization: iAnywhere Solutions Inc.
User-Agent: Mozilla Thunderbird 1.6.3.2f (Windows/20050317)
X-Accept-Language: en-us, en
MIME-Version: 1.0
Newsgroups: ianywhere.public.general
Subject: Re: problem in comunication
References: <Xns96AD582F0E7ACfishburnsybasecom@127.0.0.1> <42f8b5db.2810.1681692777@sybase.com>
In-Reply-To: <42f8b5db.2810.1681692777@sybase.com>
Content-Type: text/plain; charset=ISO-8859-1; format=flowed
Content-Transfer-Encoding: 7bit
NNTP-Posting-Host: gfenton-t30.sybase.com
X-Original-NNTP-Posting-Host: gfenton-t30.sybase.com
Message-ID: <42fa17c9$1@forums-1-dub>
Date: 10 Aug 2005 08:05:45 -0700
X-Trace: forums-1-dub 1123686345 10.25.98.243 (10 Aug 2005 08:05:45 -0700)
X-Original-Trace: 10 Aug 2005 08:05:45 -0700, gfenton-t30.sybase.com
Lines: 24
X-Authenticated-User: techsupp
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4679
Article PK: 8481


Omri wrote:
> mobilink 9.0.2.3044
> ultralite 9.0.1
> and the language is c#
> before i synchronize i'm doing ping to the computer and i
> get success.

What kind of "ping" are you doing?

> but when i use the synchronize i get communication error on
> the spot it's not even tring to make a connection it's
> throwin the exception immediatley
>

Is there by chance a firewall in place between the remote and the ML server?

greg.fenton
--
Greg Fenton
Consultant, Solution Services, iAnywhere Solutions
--------
Visit the iAnywhere Solutions Developer Community
Whitepapers, TechDocs, Downloads
http://www.ianywhere.com/developer/


Omri Posted on 2005-08-23 10:15:06.0Z
Sender: ac4.430af51a.1804289383@sybase.com
From: Omri
Newsgroups: ianywhere.public.general
Subject: Re: problem in comunication
X-Mailer: WebNews to Mail Gateway v1.1t
Message-ID: <430af724.ae2.1681692777@sybase.com>
References: <42fa17c9$1@forums-1-dub>
X-Original-NNTP-Posting-Host: 10.22.241.42
X-Original-Trace: 23 Aug 2005 03:15:00 -0700, 10.22.241.42
Lines: 18
X-Original-NNTP-Posting-Host: forums-2-dub.sybase.com
X-Original-Trace: 23 Aug 2005 03:15:03 -0700, forums-2-dub.sybase.com
NNTP-Posting-Host: forums-master.sybase.com
X-Original-NNTP-Posting-Host: forums-master.sybase.com
Date: 23 Aug 2005 03:15:06 -0700
X-Trace: forums-1-dub 1124792106 10.22.108.75 (23 Aug 2005 03:15:06 -0700)
X-Original-Trace: 23 Aug 2005 03:15:06 -0700, forums-master.sybase.com
X-Authenticated-User: ngsysop
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4709
Article PK: 17326


> Omri wrote:
> > mobilink 9.0.2.3044
> > ultralite 9.0.1

G> What kind of "ping" are you doing?
i'm doing ping from opennetcf and it's give me success.

G> Is there by chance a firewall in place between the remote
G> and the ML server?
there is a router that it's FireWall is disabled.
all the ports are open in the router.
is there a specific port that the ppc is synchronizing from?
it's very frastrating that the ppc is connecting to the bet
but gives comunication error (-85) when trying to
synchronize.

have a nice day ,

Omri Ziv


Graham Hurst Posted on 2005-08-25 14:19:55.0Z
From: Graham Hurst <spam_guard_hurst@ianywhere.com>
Organization: iAnywhere Solutions
User-Agent: Mozilla Thunderbird 0.6 (Windows/20040502)
X-Accept-Language: en-us, en
MIME-Version: 1.0
Newsgroups: ianywhere.public.general
Subject: Re: problem in comunication
References: <42fa17c9$1@forums-1-dub> <430af724.ae2.1681692777@sybase.com>
In-Reply-To: <430af724.ae2.1681692777@sybase.com>
Content-Type: text/plain; charset=us-ascii; format=flowed
Content-Transfer-Encoding: 7bit
NNTP-Posting-Host: vpn-concord-104.sybase.com
X-Original-NNTP-Posting-Host: vpn-concord-104.sybase.com
Message-ID: <430dd38b$1@forums-1-dub>
Date: 25 Aug 2005 07:19:55 -0700
X-Trace: forums-1-dub 1124979595 158.159.8.104 (25 Aug 2005 07:19:55 -0700)
X-Original-Trace: 25 Aug 2005 07:19:55 -0700, vpn-concord-104.sybase.com
Lines: 29
X-Authenticated-User: techsupp
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub ianywhere.public.general:4714
Article PK: 17369

Is the router doing network address translation (NAT)? If so, maybe the
ping is going to a different computer than the ML connection attempt.

Cheers,

Graham

Omri wrote:

>>Omri wrote:
>>
>>>mobilink 9.0.2.3044
>>>ultralite 9.0.1
>
> G> What kind of "ping" are you doing?
> i'm doing ping from opennetcf and it's give me success.
>
> G> Is there by chance a firewall in place between the remote
> G> and the ML server?
> there is a router that it's FireWall is disabled.
> all the ports are open in the router.
> is there a specific port that the ppc is synchronizing from?
> it's very frastrating that the ppc is connecting to the bet
> but gives comunication error (-85) when trying to
> synchronize.
>
> have a nice day ,
>
> Omri Ziv