PowerBuilder 6.5 datawindow causes crash

6 posts in DataWindow Last posting was on 2008-06-17 14:37:34.0Z
beaty.jeremy Posted on 2008-06-16 17:51:07.0Z
Sender: 6bd6.48569ab8.1804289383@sybase.com
From: beaty.jeremy@cleanharbors.com
Newsgroups: sybase.public.powerbuilder.datawindow
Subject: PowerBuilder 6.5 datawindow causes crash
X-Mailer: WebNews to Mail Gateway v1.1t
Message-ID: <4856a80b.6d98.1681692777@sybase.com>
NNTP-Posting-Host: 10.22.241.41
X-Original-NNTP-Posting-Host: 10.22.241.41
Date: 16 Jun 2008 10:51:07 -0700
X-Trace: forums-1-dub 1213638667 10.22.241.41 (16 Jun 2008 10:51:07 -0700)
X-Original-Trace: 16 Jun 2008 10:51:07 -0700, 10.22.241.41
Lines: 8
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87182
Article PK: 416440

I need help figuring out how to fix a datawindow that keeps
crashing. This is in Power Builder version 6.5.1 retrieving
data from a SQL database using a stored procedure. The
datawindow has the detail hidden and several summary fields
in the headers, main, group 2, and group 1. I have found
that if I don't hide the detail records the datawindow
doesn't cause a crash. I have applied the maintenance patch
for this version.


"Jerry Siegel [TeamSybase]" <jNOsSPAMsiegel Posted on 2008-06-16 19:36:45.0Z
From: "Jerry Siegel [TeamSybase]" <jNOsSPAMsiegel@yahoo!.com>
Newsgroups: sybase.public.powerbuilder.datawindow
References: <4856a80b.6d98.1681692777@sybase.com>
Subject: Re: PowerBuilder 6.5 datawindow causes crash
Lines: 19
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.5512
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.5512
X-RFC2646: Format=Flowed; Original
NNTP-Posting-Host: vip152.sybase.com
X-Original-NNTP-Posting-Host: vip152.sybase.com
Message-ID: <4856c0cd$1@forums-1-dub>
Date: 16 Jun 2008 12:36:45 -0700
X-Trace: forums-1-dub 1213645005 10.22.241.152 (16 Jun 2008 12:36:45 -0700)
X-Original-Trace: 16 Jun 2008 12:36:45 -0700, vip152.sybase.com
X-Authenticated-User: TeamSybase
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87185
Article PK: 416441

If my rusty memory serves, build 1299 of 6.5.1 was quite stable.
Can you be specific about the symptoms of the crash?
By "hide" do you mean setting the height of the detail band to 0? How about
1?
You don't have to have visual columns for the contents to be used in summary
computed fields, but it does help for testing.

<beaty.jeremy@cleanharbors.com> wrote in message
news:4856a80b.6d98.1681692777@sybase.com...
>I need help figuring out how to fix a datawindow that keeps
> crashing. This is in Power Builder version 6.5.1 retrieving
> data from a SQL database using a stored procedure. The
> datawindow has the detail hidden and several summary fields
> in the headers, main, group 2, and group 1. I have found
> that if I don't hide the detail records the datawindow
> doesn't cause a crash. I have applied the maintenance patch
> for this version.


beaty.jeremy Posted on 2008-06-16 20:13:59.0Z
Sender: 6bd6.48569ab8.1804289383@sybase.com
From: beaty.jeremy@cleanharbors.com
Newsgroups: sybase.public.powerbuilder.datawindow
Subject: Re: PowerBuilder 6.5 datawindow causes crash
X-Mailer: WebNews to Mail Gateway v1.1t
Message-ID: <4856c987.72e3.1681692777@sybase.com>
References: <4856c0cd$1@forums-1-dub>
NNTP-Posting-Host: 10.22.241.41
X-Original-NNTP-Posting-Host: 10.22.241.41
Date: 16 Jun 2008 13:13:59 -0700
X-Trace: forums-1-dub 1213647239 10.22.241.41 (16 Jun 2008 13:13:59 -0700)
X-Original-Trace: 16 Jun 2008 13:13:59 -0700, 10.22.241.41
Lines: 24
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87186
Article PK: 416442

Thanks for your help. The crash is a general protection
fault. And by hiding I do mean setting the height of the
detail band to 0. I tried 4 (it doesn't take 1, jumps in
intervals of 4 or 5) and it didn't crash but had the side
effect of having varying sized gaps between rows, this
because the number of detail rows combined into one summary
row varies between 1 and 10. As best as I can tell I have
build 444 of version 6.5.1. I downloaded and installed an
EBF/Patch dated in 1999, but I haven't seen a difference nor
have I been able to determine which build number it is. Can
you clarify how to get build 1299 for version 6.5.1?

> If my rusty memory serves, build 1299 of 6.5.1 was quite
> stable. Can you be specific about the symptoms of the
> crash? By "hide" do you mean setting the height of the
> detail band to 0? How about 1?
> You don't have to have visual columns for the contents to
> be used in summary computed fields, but it does help for
> testing.
>
> <beaty.jeremy@cleanharbors.com> wrote in message
> news:4856a80b.6d98.1681692777@sybase.com...
> >I need help figuring out how to fix a datawindow that
> > keeps crashing. This is in Power Builder version 6.5.1


"Jerry Siegel [TeamSybase]" <jNOsSPAMsiegel Posted on 2008-06-16 21:22:27.0Z
From: "Jerry Siegel [TeamSybase]" <jNOsSPAMsiegel@yahoo!.com>
Newsgroups: sybase.public.powerbuilder.datawindow
References: <4856c0cd$1@forums-1-dub> <4856c987.72e3.1681692777@sybase.com>
Subject: Re: PowerBuilder 6.5 datawindow causes crash
Lines: 36
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.5512
X-RFC2646: Format=Flowed; Original
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.5512
NNTP-Posting-Host: vip152.sybase.com
X-Original-NNTP-Posting-Host: vip152.sybase.com
Message-ID: <4856d993$1@forums-1-dub>
Date: 16 Jun 2008 14:22:27 -0700
X-Trace: forums-1-dub 1213651347 10.22.241.152 (16 Jun 2008 14:22:27 -0700)
X-Original-Trace: 16 Jun 2008 14:22:27 -0700, vip152.sybase.com
X-Authenticated-User: TeamSybase
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87188
Article PK: 416445

I think you need to look at the properties of the DLLs in Windows Explorer
in C:\Program Files\Sybase\Shared\PowerBuilder. PB65.exe won't have a useful
version - it is a stub that just loads the others. IIRC the last release was
around 1358 - there doesn't seem to be a lot of choices in the download
list.
If upgrading to a supported version is not a possibility, make a copy and
try removing the visual columns and see if that fixes it.

<beaty.jeremy@cleanharbors.com> wrote in message
news:4856c987.72e3.1681692777@sybase.com...
> Thanks for your help. The crash is a general protection
> fault. And by hiding I do mean setting the height of the
> detail band to 0. I tried 4 (it doesn't take 1, jumps in
> intervals of 4 or 5) and it didn't crash but had the side
> effect of having varying sized gaps between rows, this
> because the number of detail rows combined into one summary
> row varies between 1 and 10. As best as I can tell I have
> build 444 of version 6.5.1. I downloaded and installed an
> EBF/Patch dated in 1999, but I haven't seen a difference nor
> have I been able to determine which build number it is. Can
> you clarify how to get build 1299 for version 6.5.1?
>
>> If my rusty memory serves, build 1299 of 6.5.1 was quite
>> stable. Can you be specific about the symptoms of the
>> crash? By "hide" do you mean setting the height of the
>> detail band to 0? How about 1?
>> You don't have to have visual columns for the contents to
>> be used in summary computed fields, but it does help for
>> testing.
>>
>> <beaty.jeremy@cleanharbors.com> wrote in message
>> news:4856a80b.6d98.1681692777@sybase.com...
>> >I need help figuring out how to fix a datawindow that
>> > keeps crashing. This is in Power Builder version 6.5.1


Roland Smith [TeamSybase] Posted on 2008-06-16 23:08:47.0Z
From: "Roland Smith [TeamSybase]" <topwiz.smith@comcast.net>
Newsgroups: sybase.public.powerbuilder.datawindow
References: <4856c0cd$1@forums-1-dub> <4856c987.72e3.1681692777@sybase.com>
Subject: Re: PowerBuilder 6.5 datawindow causes crash
Lines: 13
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.3138
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.3198
X-RFC2646: Format=Flowed; Original
NNTP-Posting-Host: vip152.sybase.com
X-Original-NNTP-Posting-Host: vip152.sybase.com
Message-ID: <4856f27f$1@forums-1-dub>
Date: 16 Jun 2008 16:08:47 -0700
X-Trace: forums-1-dub 1213657727 10.22.241.152 (16 Jun 2008 16:08:47 -0700)
X-Original-Trace: 16 Jun 2008 16:08:47 -0700, vip152.sybase.com
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87189
Article PK: 416446

The download "PowerBuilder - 6.5.1 Maintenance Release for Windows" dated 25
May 1999 is build 620. That is the latest build I see in the Download
EBF/Maintenace center. The only newer downloads are localized 'Y2K'
downloads. I would have to assume the Y2K fixes were included in the
standard build 620.

I remember that being a problem. Build 620 was the highest I ever used but I
don't remember if it corrected it or not.

You could manually change the band height to 1 by exporting the source,
editing it in Notepad and then importing it.


Terry Dykstra Posted on 2008-06-17 14:37:34.0Z
Reply-To: "Terry Dykstra" <dontreply_tddykstra@forestoil.ca.x>
From: "Terry Dykstra" <tddykstra@forestoil.ca>
Newsgroups: sybase.public.powerbuilder.datawindow
References: <4856c0cd$1@forums-1-dub> <4856c987.72e3.1681692777@sybase.com>
Subject: Re: PowerBuilder 6.5 datawindow causes crash
Lines: 44
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.3138
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.3198
X-RFC2646: Format=Flowed; Original
NNTP-Posting-Host: vip152.sybase.com
X-Original-NNTP-Posting-Host: vip152.sybase.com
Message-ID: <4857cc2e$1@forums-1-dub>
Date: 17 Jun 2008 07:37:34 -0700
X-Trace: forums-1-dub 1213713454 10.22.241.152 (17 Jun 2008 07:37:34 -0700)
X-Original-Trace: 17 Jun 2008 07:37:34 -0700, vip152.sybase.com
X-Authenticated-User: TeamSybase
Path: forums-1-dub!not-for-mail
Xref: forums-1-dub sybase.public.powerbuilder.datawindow:87195
Article PK: 416452

I used 1299 as well. I believe 1326 was the last EBF available, but I don't
know if you can still download that from the website. Those EBFs requires
that you have the MR 6.5.1 installed. I have a copy of 1299 if you can't
find it online.
The issue with not being able to set heights to 1 has to do with the fact
you have 'snap to grid' turned on. Disable that option and then you can set
the band height to any desired value.
Ultimately, you should seriously consider upgrading to a supported version.
11.2 is the latest release, with 11.5 in beta right now.
--
Terry Dykstra (TeamSybase)
http://powerbuilder.codeXchange.sybase.com/
http://casexpress.sybase.com
product enhancement requests:
http://my.isug.com/cgi-bin/1/c/submit_enhancement

<beaty.jeremy@cleanharbors.com> wrote in message
news:4856c987.72e3.1681692777@sybase.com...
> Thanks for your help. The crash is a general protection
> fault. And by hiding I do mean setting the height of the
> detail band to 0. I tried 4 (it doesn't take 1, jumps in
> intervals of 4 or 5) and it didn't crash but had the side
> effect of having varying sized gaps between rows, this
> because the number of detail rows combined into one summary
> row varies between 1 and 10. As best as I can tell I have
> build 444 of version 6.5.1. I downloaded and installed an
> EBF/Patch dated in 1999, but I haven't seen a difference nor
> have I been able to determine which build number it is. Can
> you clarify how to get build 1299 for version 6.5.1?
>
>> If my rusty memory serves, build 1299 of 6.5.1 was quite
>> stable. Can you be specific about the symptoms of the
>> crash? By "hide" do you mean setting the height of the
>> detail band to 0? How about 1?
>> You don't have to have visual columns for the contents to
>> be used in summary computed fields, but it does help for
>> testing.
>>
>> <beaty.jeremy@cleanharbors.com> wrote in message
>> news:4856a80b.6d98.1681692777@sybase.com...
>> >I need help figuring out how to fix a datawindow that
>> > keeps crashing. This is in Power Builder version 6.5.1